Roof and module layout
We check roof area, orientation, pitch and shading from mountains, trees or neighbouring buildings. Tiled, slate, metal and flat roofs each need a suitable mounting system.
Merano · Burgraviato · Bolzano · South Tyrol
We design and install your solar system from the first roof check to commissioning, with battery, EV charger and heat pump if you wish. A qualified electrician is your single point of contact. Advice in English, German and Italian.
We check roof area, orientation, pitch and shading from mountains, trees or neighbouring buildings. Tiled, slate, metal and flat roofs each need a suitable mounting system.
Inverter, cable routes, surge protection, breakers and meter cabinet are designed and installed to current standards, with grid connection under CEI 0-21.
A battery shifts solar power into the evening. Energy management sends surplus to the EV charger, hot water or heat pump.
We prepare the grid connection, usually via the simplified Modello Unico for small systems, plus Terna GAUDÌ registration and, if wanted, GSE export payments.
Our planning range is €1,300–1,600 gross per kWp of solar and €300–500 per usable kWh of battery storage. Typical budgets:
| System | Typical use | Gross planning range |
|---|---|---|
| 6 kWp | Detached house, normal consumption | €7,800 – 9,600 |
| 10 kWp | House with heat pump or EV | €13,000 – 16,000 |
| 10 kWp + 10 kWh battery | More solar power in the evening | €16,000 – 21,000 |
| 15 kWp + 15 kWh battery | Large house, farm, small business | €24,000 – 31,500 |
Price depends mainly on roof shape and access, scaffolding, cable routes, meter cabinet and any backup function. Incentives and tax deductions are not deducted. Only our quotation after a site visit is binding.
In Merano, 1 kWp facing south at 30° produces about 1,330 kWh a year according to PVGIS, without shading. In valley floors and on north-facing slopes, mountain shade can cut winter yield considerably, so we assess every roof individually.
The main value comes from electricity you use yourself: grid power costs far more than exported power earns. With a heat pump, EV or battery you use more solar power at home, so a larger system often makes sense.
Our solar calculator uses hourly weather data for Merano, Bolzano and Bressanone and shows yield, self-consumption and payback over 25 years.
Calculate solar yield
Several module fields on a complex tiled roof, planned around chimneys and roof steps.

Installation around roof windows, finished system between orchards and mountains.

Dark modules on several roof areas, combined with an LFP battery.
Location, annual consumption and a roof photo are enough for a first assessment.
We check roof, meter and plant room. You receive a module plan and options with and without storage.
Mounting, modules, inverter, battery and protection. We handle the grid registration.
We explain the system and app, check the first data and remain your contact.
System, battery and charger matched to your consumption. In new builds we plan cables and meter cabinet from the start.
Shared systems for stairwell, lift and charging, or joining a renewable energy community (CER).
Trades, retail and hospitality use a lot of power during the day, which suits solar, as the 40 kWp system in Burgstall shows.
Large barn and outbuilding roofs, combined with storage and load management.
From Merano we quickly reach:
Projects in Val Venosta, Val Passiria and the rest of South Tyrol by arrangement.
FAQ
It depends on roof area, orientation and consumption. A household using 4,500 kWh a year in Merano would need about 3.5 kWp on paper. With a heat pump, EV or battery, a larger system often makes sense because you use more solar power at home.
On existing roofs in South Tyrol, solar is often possible without a building permit. Protected ensembles, listed buildings or landscape protection areas can have conditions. We check this with the municipality first.
Mounting a detached house usually takes one to three days. Overall timing depends on design, delivery times and grid registration.
In 2026 a 50% tax deduction applies to the principal residence, otherwise 36%, spread over ten years. The 2026 provincial grants are closed. We check the 2027 conditions as soon as they are published.
It is exported to the grid and can be paid for via the GSE. It is usually worth more at home: in a battery, EV, hot water or heat pump. Another option is a renewable energy community (CER).
Often yes. We check inverter, meter cabinet and roof space. A battery can often be added too.
We are not tied to any manufacturer. We choose modules, inverters and batteries by roof, consumption, warranty and availability. The quotation lists every component with its data sheet.
Yes. With on-site measurements and, if needed, a grid analysis we find the cause, for example shutdowns due to high grid voltage, insulation faults, shading or incorrect settings.
Send us your location and a roof photo via the form or WhatsApp for a first assessment.